Industry informationHome>Industry information > Storage Precautions for KMS Series Generator Set

Storage Precautions for KMS Series Generator Set

Time:2025-05-26 16:10:47  Edit:HuaQuan
Proper storage procedures are critical for preserving the performance and longevity of the KMS series generator set during periods of inactivity. Whether for short-term or extended storage, following the correct guidelines helps prevent corrosion, fuel degradation, and component damage. Below are essential storage considerations for the KMS series generator set.
KMS series generator set
1. Preparation Before Storage for KMS Series Generator Set
Before storing the KMS series generator set, conduct a thorough inspection to ensure all components are in good condition. Check for leaks, loose connections, and signs of wear. Clean the exterior to remove dirt, grease, and debris that could cause corrosion over time.
 
2. Fuel System Maintenance
If the KMS series generator set will be stored for an extended period, stabilize the fuel by adding a fuel stabilizer and running the engine for a few minutes to circulate treated fuel through the system. Alternatively, drain the fuel tank and fuel lines completely to prevent gum formation and clogging.
 
3. Battery Care for KMS Series Generator Set
Disconnect the battery from the KMS series generator set and store it in a cool, dry place. Keep it fully charged and periodically recharge it during long-term storage to prevent sulfation and capacity loss.
 
4. Lubrication and Corrosion Prevention
Change the engine oil before storage to remove contaminants that could degrade internal components. Apply a light coating of rust inhibitor to exposed metal surfaces to prevent oxidation.
KMS series generator set
5. Proper Storage Environment for KMS Series Generator Set
Store the KMS series generator set in a dry, well-ventilated area away from direct sunlight and extreme temperatures. If possible, cover it with a breathable, moisture-resistant cover to protect against dust while allowing air circulation.
 
6. Periodic Maintenance During Storage
Even when not in use, the KMS series generator set should be inspected periodically. Rotate the engine manually every few months to prevent bearing wear and check for signs of moisture or pest infestation.
 
7. Reactivation After Storage
Before returning the KMS series generator set to service, perform a full inspection, replace fluids if necessary, and test-run the unit to ensure proper operation.
 
By following these storage precautions, users can ensure that their KMS series generator set remains in optimal condition, ready for reliable operation when needed.
More information about Huaquan Power:http://www.huaquandl.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD